Contact Us: 1-800-542-4448

SG赛车玩法技巧

This version of DataTracker and the user guide are still in beta testing.  Please provide any user feedback, enchancement requests or report bugs to QuinTron.

SG赛车开奖号

Set up or edit any of the system preferences in System Configuration.

Company Information – Click Setup to enter company information such as phone, fax, company name, and logo.  The company logo will appear on finalized reports.

Nurses/Technicians – This module allows you to enter or edit nurse/technician and referring physician information.  Enter the information within each box.  To save after entry completion, press the Tab key on your keyboard to advance to the next field.  Once complete the Save icon is enabled to save the data entered.

Physicians – This module allows you to enter or edit nurse/technician and referring physician information.  Enter the information within each box.  To save after entry completion, press the Tab key on your keyboard to advance to the next field.  Once complete the Save icon is enabled to save the data entered.

Privacy Mode – When enabled (“On”) DataTracker masks patient first and last names and will only display the Patient ID field throughout the software. Privacy Mode does not mask patient information on finalized/generated reports.

Instrument Model – DataTracker defaults to the BreathTracker SC breath analyzer.  Click the Edit link to change the analyzer model.  Each model displays corresponding gases available for analysis on each report.

Date Format – Choose desired date format.

Bluetooth – Connects DataTracker to a BreathTracker Bluetooth source for analysis results to be accumulated in the BT Data tab for later assignment to a specific test.

Language and Labels – Default language is English. Enter any modifications to the language in the modified fields, select Update Language Settings when finished. Select Reset to reset the language to the original language file provided at installation (all modifications will be lost). 

Each tab within the language settings corresponds to various areas throughout DataTracker.
No warning messages can be changed to languages other than English.

Certain fields may be hidden by clicking the hide/unhide icon to the right of non-mandatory fields.

SG赛车开奖直播

Choose an existing patient, test type, nurse/technician and referring physician or select the New link to open a new entry screen for that area.  Once a test is created, it cannot be deleted.  If a test is accidentally created, finalize the test and enter any notes in the pop-up window.

Select the date samples were collected and the date samples were analyzed. 

SG赛车开奖结果时间

This module allows you to enter new patient information.

All fields are optional except Patient ID and patient Last Name. 

 

SG赛车开奖结果

This module allows you to enter or edit nurse/technician and referring physician information.  Enter the information within each box.  To save after entry completion, use the Tab key on your keyboard to advance to the next field.  Once complete the Save icon will enable.

 

SG赛车龙虎和走势图

There are standard preset breath test protocols for carbohydrate malabsorption/intolerance and Small Intestinal Bacterial Overgrowth (SIBO) located in the Test Type drop down field.

SG赛车两期精准计划

 

Fructose Malabsorption

  • Baseline + additional 3 samples collected every 60 minutes for 3 hours. (4 Samples Total)

Lactose Malabsorption

  • Baseline + additional 3 samples collected every 60 minutes for 3 hours. (4 Samples Total)

Small Intestinal Bacterial Overgrowth (Glucose)

  • Baseline + additional 9 samples collected every 20 minutes for 3 hours. (10 Samples Total)

Small Intestinal Bacterial Overgrowth (Lactulose)

  • Baseline + additional 9 samples collected every 20 minutes for 3 hours. (10 Samples Total)

Sucrose Malabsorption         

  • Baseline + additional 6 samples collected every 30 minutes for 3 hours. (7 Samples Total)

 

Select a preset common dose for the chosen substrate or enter a specific dose administered.

Select/enter the date the samples were collected and the date the samples were analyzed.

Select any pre-test symptoms and enter any pre-test notes to appear on the final report.

All pre-test information is stored within the DataTracker software.

 

SG赛车计划全天

To create a custom breath test, click the New link to the right of the test type drop-down menu within the New Test screen.

Press the Tab key on your keyboard to advance through each field.  Enter the custom name for the protocol. 

Choose the desired available substrate from the drop-down menu. 

Enter the intervals in minutes which breath samples will be collected.

Enter the total desired amount of samples to be collected (including baseline/control sample).

After pressing the Tab key on your keyboard to exit the last field, the Save icon is enabled which allows the custom breath test to be saved for future use.

An unlimited amount of custom protocols may be saved.

To modify an existing custom protocol, change the conditions within the fields and click Save when finished.

To delete an existing custom protocol, select the line and click the Delete icon.

To add a new custom protocol from within the Custom Breath Test screen, enter new protocol information on the top line.  Press the Tab key on your keyboard to advance through all fields, click Save when complete.

 

SG赛车历史开奖号码

The In Progress tab displays breath tests that have not been finalized.  Non-finalized tests are listed on the left side of the application.  Selecting a patient will display the current data and progress of the test on the right side of the application.  Data entry for each sample may be added or edited within this screen.  Click Add to insert additional samples or click delete to remove samples. 

SG赛车人工计划软件

Select the specific cell within the Data Entry screen to enter error codes displayed by the BreathTracker analyzer.  Once the cell is selected, click the OVR, MAX or TOO HIGH buttons to insert the error message into the specific cell.  It is important to match the BreathTracker error message to the specific cell within the data entry screen.

SG赛车冷热号统计

To skip a sample, select the data entry line and click on the Skip button.  The entire line will then be disabled. To undo a skipped sample, select the sample line and click Unskip.

SG赛车开奖号码查询

After all data entry for the breath test is complete, click Finalize to complete the test and generate a PDF report.  Print and/or save the PDF as you normally would in your PDF application software.  View, reopen, and regenerate reports from finalized tests from the Reports tab.  Any test reopened will require notes to be entered and will require it to be finalized again to close.  Previous PDF reports generated for a specific test are not overwritten.

SG赛车计划5码一期

Each report will contain patient information, pre-test notes, pre-test symptoms, in-test notes and symptoms, numerical values for each breath sample entered in DataTracker, and a graphical representation of the numerical values.  Any breath samples which were skipped or contained an error from the breath analyzer appear as a dashed line; indicating that the sample was not valid and is not being considered for review.

 

 

 

SG赛车最快开奖结果

 

Additional help and this User Guide is available at http://www.breathtests.com/dthelp

 

Corporate Website: www.BreathTests.com

Phone: (414)645-4222

Fax: (414)645-3484

Toll-Free (US & Canada): (800)542-4448

E-mail: Support@QuinTron-USA.com

SG赛车在线计划 澳洲5官方网站 澳洲8结果 秒速飞艇开奖最快 SG赛车下载